View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0004380 | Networks | [All Projects] Special | public | 2021-12-05 20:14 | 2023-11-24 23:33 |
Reporter | DigitalMy | ||||
Priority | normal | Severity | minor | Reproducibility | have not tried |
Status | assigned | Resolution | open | ||
Summary | 0004380: Video surviellance cameras streams | ||||
Description | Set video cameras in IP network. Use D-link DCS- models as default. New cam get 2mpx or better resolution. | ||||
Steps To Reproduce | For camera model DCS-2230 stream URL is: rtsp://user:pass@10.17.177.155:554/live1.sdp | ||||
Tags | No tags attached. | ||||
|
DCS-7000L got 4pcs installed inside and outside (under roof) 720p devide use motion detection mode for recording 1) video_SD profile for local records 2) video profile for server records |
|
Got DCS-6112 A2 for test D=130mm round internal LAN port PoE 1920x1080 12V 4.4W no power up with LAN POE +12V DC because it must be IEEE 802.3af PoE power source (802.3at Type 1) 44.0–57.0 V now powers only from DC IN connector +12V Tested 48V DC PoE works fine Got DCS-6112V works fine for recording to SD, but no motion detection It uses .mov format on web config page |
|
Got error 404 (not found) for main page on port 80 Connected to port 21 as admin root:*:0:0:*:/mnt/ramdisk:/bin/sh admin::0:0:83a23ab2f31bd7263c63ae6b97e0638d:/mnt/ramdisk:/bin/sh it has protocols enabled: landap 62976/udp telnet ftp |
|
Change video camera to 5MP H.265 rubetek RV-3420 > got 4pcs Resolution 2592*1944px PoE 48V (use 54V as standard 802.3af) and 12V power socket works dvripc.com sectec.com.cn - offered Xmeye type and IPC default DHCP assigned IP address gives web page on port 80, user: admin without password - works in IE with plugin media port 34567 onvif port 8899 firmware V4.02.R12.00039840.11012.144900.00200 IPC saves only pictures to network FTP share, video should be captured from NVR These formats do work for rubetek RV-3420 (tested): rtsp://199.255.20.999:554/user= login&password=pswrd& channel=1&stream=0.cgi rtsp://10.6.3.57:554/user=admin&password=&channel=1&stream=0.sdp? rtsp://10.10.10.53:554/user=admin&password=1111&channel=0&stream=0 stream - may be 0 or 1 as set in IPC config channel - any value |
|
Tested microcontrolled PoE adapters: D-Link DPE-301GI 54V D-Link DPE-101GI 48V |