View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0007499 | vehicle service | Suzuki EVERY | public | 2025-06-17 00:27 | 2025-06-22 20:34 |
Reporter | DigitalMy | ||||
Priority | normal | Severity | minor | Reproducibility | have not tried |
Status | assigned | Resolution | open | ||
Summary | 0007499: Clean injector and test spraying | ||||
Description | DA64V K6A engine has got 3 nozzles each injector 2-pin: +12V GND | ||||
Steps To Reproduce | ramp 8218-1 delivery pipe /15730-68H00-000 new injector 15007XU /15710-65H00-000 installed before version 15009ZF (D5 D6 D7) -> removed | ||||
Tags | No tags attached. | ||||
|
|
|
Make cleaning stand including: fuel (cleaning liquid) tank fuel pump hose as standard d=7.5mm fuel filter pressure meter return valve injector holder single injector measuring volume |
|
Made fast cleaning of injectors, 15 minutes ultrasonic bath 120W, replaced as follows: C1: "D6" nozzle C2: "D7" nozzle C3: "D8" nozzle -> each 15007XU -> no stop happen on idle now, but it used to "fix" itself earlier |