View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000089 | vehicle service | Toyota SERA | public | 2014-03-22 22:11 | 2024-08-21 18:21 |
Reporter | DigitalMy | ||||
Priority | high | Severity | major | Reproducibility | N/A |
Status | checking | Resolution | open | ||
Summary | 0000089: Replace engine starter and fix stable start on Toyota Sera | ||||
Description | It is not starting engine from key on each turn, only with manual bridging of contacts on starter (battery to relay). Possibly it is retract relay (in starter contactor) issue or cord connector. This car model does not have starter relay yet: add such a relay (like in model 1995) for more stable starter function. | ||||
Tags | No tags attached. | ||||
|
Starter relay is shown on parts scheme 28300 RELAY ASSY, STARTER, but has got no part number for SERA01 SERA02... only SERA03 /28300-10020 (12V Denso 156700-0503) for fuse and relay block /82660-10130 similar relay to check is: 85915 RELAY, MAIN /90987-02006 -> relay has no problem, because I have solenoid sound on each ignition key turn to "start" there is alternative solution to install mentioned relay on SERA01 additional: to clean ground terminals on both engine sides L\R |
|
|
|
Replaced starter to 28100-11020 (0.8kW) - original for EXY10. was 28100-16230 (0.8kW). starter /28100-10060 fits Sera 1kW Need lower starter bolt /91612-61045 and high load (80A) cord connector (from battery to alternator wire) as specified on fuse box -> this part still needs to be replaced, both wire and terminal measured: Accumulator is 12.29V and above in standby (new battery Varta 5634010613162 "silver dynamic" 63Ah gives 12.6V in installed state, and 12.8V during disconnected from car). Engine starts normally now each time - problem almost solved Real problem of starter was in wiring and oxidized terminals: install more powerful and solid connectors, hide from moist with insulating cover, apply protective paste to battery and lock contact pads as well. clean inside of starter dust see black wire from battery |
|
Need tools for this work: sandpaper abrasive sponge, all-size spanner and wrench, SATA tool, long stall ratchet |
|
found BREAKER ASSY, WIRING CIRCUIT, NO.1 /82650-20011 and heater relay /90987-04002 on the left board and screw 93319-15010 lost to secure COMPUTER, ENGINE CONTROL /get \GOT |
|
Cannot apply screw 91612-61045 on starter -> video research |
|
relay_fuse_EXY10.JPG (273,644 bytes) |
|
|
|
|
|
|
|
|
|
high power wires from battery: black to starter white+blue to fuse from fuse: white white+blue white+red |
|
Got used starter from black Sera 0.8kW 12V Denso /28100-11020 test and clean and fix - disassembled 2021 Got normal 0.8kW starter Toyota /28100-11010 Denso /128000-8530 "69" (9 teeth) |
|
Connect additional relay high load line to W-R (AM1) and B-W to starter terminal power up starter relay from R-W "ST1" line after neutral-parking start switch and GND to frame Got another Main relay Toyota /90987-02006 Denso 056700-6912 12V normally open relay from donor car it is targeted to double 30A lines .... so, must be enough |